• 东湖高新技术开发区关山大道60号光谷科技产业园8栋
  • 武汉, Hubei, 430074
  • 中国
  • 電話番号:+86-153 2720 6266
  • スカイプ:nanaoelec@yahoo.com
  • ウェブページ:

NADXC power harmonic measuring tester

変圧器製造プラントおよび設備、一式

¥ or 元 23000 CNY / ユニット

新しい

3 年(S)

中国

問い合わせる

製品記述

The main performance and technical indicators

This power quality of the power grid is a measure of the quality of the power supplied to the user at the receiving end and for the user to use. It covers five aspects: supply voltage tolerance, utility harmonic, three-phase voltage unbalance, power system frequency tolerance, voltage fluctuation and flicker.

NADXB power harmonic measurement alarm object for the 45 ~ 65Hz AC frequency measurement of the signal, The specific technical parameters are as follows:

1. Measurement accuracy:

Table 1. main instrument performance and technical indicators

Data Measuring range Working error Resolution Remarks

AC Voltage ( 10~500)V ±(0.4%Reading + 0.1% of range) 0.1V Max:600V

AC Current Current clamp can option 0.001A Max:1.1 times

Power U*I*PF PF=1.0:±(0.4%Reading + 0.1% of range)

PF=0.5:±(0.8%Reading + 0.2% of range) < 200W 0.1W

≥200W 1W Test current > 0.01*Current range

Power factor 0.20~1.00 ±0.02 0.01 > 0.5A;

Frequency (45~65)Hz ±0.01 Hz 0.01 Hz U > 50 V

Electricity 9999.9 MWh PF=1.0:±(0.4%Reading + 0.1% of range)

PF=0.5:±(0.8Reading + 0.2% of range)

Time 1m~999h59m ±0.05 % 1 Second

Harmonics 1~50 times

Real time 24 Hour Format 1 Second

Note: The current range of reference meter matching current clamp, customer orders should confirm the appropriate current clamp.

2. Other parameters:

Input mode: voltage and current are floating input;

Input impedance: Voltage terminals: ≥ 600 kΩ;

Current terminal: current clamp

Measurement signal maximum peak: voltage and current are 1.6 times the maximum range;

Conversion rate: about 20,000 times / second;

Display update: about 2 times / sec;

Power consumption:


輸出入

1.00 ユニット

本船渡し, 費用、保険、貨物

T/T