Duodenal Stents

Медицинско оборудване

$ 100 USD / Части

Нов

Не е налично

Не е налично

Запитвам

Описание на продукта

The self-expanding Nitinol stents are used to bypass stenoses in the duodenum. Their spherical ends adapt perfectly to the anatomy of the duodenum, thereby guaranteeing maximum positional stability. Stents with and without covering are available depending on the indication.

The duodenal stent is preloaded on a TTS introducer (through-the scope) as standard. Insertion can therefore be performed through the working channel of the endoscope and the stent can be released under endoscopic observation. X-ray markings on the introducer and on the stent ensure optimum radiological visualisation.

Successful in practical use

The X-ray images show the release process under radiological monitoring. The good radiopacity plus additional X-ray markings on the stent assist orientation and facilitate the release of the duodenal stent. The endoscopic position control clarifies the stent’s optimum expansion.

Always the appropriate solution

With a diameter of 20 mm and different lengths of 60, 80 or 100 mm, the range of duodenum stents always offers you the right size for your patient.

Duodenal Stents

KEY BENEFITS

Spherical ends

Self-expanding

Nitinol mesh with atraumatic ends

Release under endoscopic observation

Excellent positional stability

Resistant and elastic covering

High radiopacity

Extraction threads for removal and repositioning

Compatible guide-wire up to 0.035 inches

SPECIFICATION

Duodenal Stents

REF Stent Delivery System

Body O.D. (mm) Expanded Length

(mm) Catheter O.D.

(Fr/mm) Working Length

(mm) Packaging Repositionable

Duodenal Stents Non-Covered

ST74-331-20.060 20 60 10/3.3 1800 1/Box \

ST74-331-20.080 20 80 10/3.3 1800 1/Box \

ST74-331-20.100 20 100 10/3.3 1800 1/Box \

Duodenal Stents Partially-Covered

ST74-332-20.060 20 60 10.5/3.5 1800 1/Box \

ST74-332-20.080 20 80 10.5/3.5 1800 1/Box \

ST74-332-20.100 20 100 10.5/3.5 1800 1/Box \