• No. 10, Gaoke 3rd Road, National Hi-Tech Zone, Nanjing, China
  • Nanjing, Jiangsu, 210032
  • الصين
  • هاتف:025-58646393
  • فاكس: ---.---.-----
  • موقع إلكتروني:

Duodenal Stents

المعدات الطبية

$ 100 USD / قطعة

جديد

غير متوفرة

غير متوفرة

استعلم

وصف المنتج

The self-expanding Nitinol stents are used to bypass stenoses in the duodenum. Their spherical ends adapt perfectly to the anatomy of the duodenum, thereby guaranteeing maximum positional stability. Stents with and without covering are available depending on the indication.

The duodenal stent is preloaded on a TTS introducer (through-the scope) as standard. Insertion can therefore be performed through the working channel of the endoscope and the stent can be released under endoscopic observation. X-ray markings on the introducer and on the stent ensure optimum radiological visualisation.

Successful in practical use

The X-ray images show the release process under radiological monitoring. The good radiopacity plus additional X-ray markings on the stent assist orientation and facilitate the release of the duodenal stent. The endoscopic position control clarifies the stent’s optimum expansion.

Always the appropriate solution

With a diameter of 20 mm and different lengths of 60, 80 or 100 mm, the range of duodenum stents always offers you the right size for your patient.

Duodenal Stents

KEY BENEFITS

Spherical ends

Self-expanding

Nitinol mesh with atraumatic ends

Release under endoscopic observation

Excellent positional stability

Resistant and elastic covering

High radiopacity

Extraction threads for removal and repositioning

Compatible guide-wire up to 0.035 inches

SPECIFICATION

Duodenal Stents

REF Stent Delivery System

Body O.D. (mm) Expanded Length

(mm) Catheter O.D.

(Fr/mm) Working Length

(mm) Packaging Repositionable

Duodenal Stents Non-Covered

ST74-331-20.060 20 60 10/3.3 1800 1/Box \

ST74-331-20.080 20 80 10/3.3 1800 1/Box \

ST74-331-20.100 20 100 10/3.3 1800 1/Box \

Duodenal Stents Partially-Covered

ST74-332-20.060 20 60 10.5/3.5 1800 1/Box \

ST74-332-20.080 20 80 10.5/3.5 1800 1/Box \

ST74-332-20.100 20 100 10.5/3.5 1800 1/Box \

If you want to know more kinds of duodenal stent removal, duodenal stent insertion, please visit our website.

Now the price of endoscopy instrument is reasonable, if you are interested, please contact us.

Micro tech china is committed to providing high-quality solutions foendoscopic diagnosis and treatment for global medical institutions, and its products areexported to developed countries such as the United States, Germany, and Japan.