NAVLF high voltage generator, NAVLF high voltage generator, programmable NAVLF frequency high voltage generator, NAVLF frequency AC high voltage testing equipment, NAVLF frequency withstand testing equipment, NAVLF frequency generator.
Produktbeskrivning
Product introduction
NAVLF Ultra-low Frequency High Voltage Generator combines the modern digital frequency advanced technology, uses computer control, boost, buck and measurement, automatically full protection, and in the process can automatically boost can carry a manual intervention in the process of automatically boosting. Since all with electronic, is small and light, large-screen LCD displayed, clear and intuitive, printer out testing report. The Design indicators is in full compliance "special test equipment electrical equipment General technical conditions, Part 4: ultra-low frequency high voltage generator general technical conditions" power industry standard, easy to use. Nowadays home and abroad adopted mechanical approach to produce NAVLF modulation and demodulation to generate signal, so there is no standard sine waveform, and measurement error is large, high-voltage part with a spark discharge, heavy equipment, and the two and four-quadrants of sine wave, need large power high voltage resistance to discharge and sharp, the total total power consumption is very large. The NAVLF Ultra-low Frequency High Voltage Generator can overcome these shortcomings.
Also called name
NAVLF high voltage generator, NAVLF high voltage generator, programmable NAVLF frequency high voltage generator, NAVLF frequency AC high voltage testing equipment, NAVLF frequency withstand testing equipment, NAVLF frequency generator.
The Characteristics of the products
1, Advanced technology: Using digital frequency conversion technology, microcomputer controlled, boost, buck, measurement, protection and full automated testing process
2, Easy to operate: Wiring is simple, easy to move and operation
3, Comprehensive protection : Multiple protection (overload protection, high and low voltage over current protection), prompt action (action time ≤ 20ms), is a safe and reliable instrument
4, Safe and reliable: the controller and high-voltage generator voltage connection via low voltage, photoelectric control, safety and reliability.
5, Using a high-pressure closed-loop negative feedback control circuit, the output capacity without capacity boost effect
6, Fully equipped: large LCD display, automatic storage, automatic printing
7, Large test range: 0.1Hz, 0.05Hz and 0.02Hz multi-frequency selection, large testing range
8, Small in size, light in weight: is conducive to outdoor work
The parameters of the products
1, The output voltage: see table below
2, The output frequency: 0.1Hz, 0.05Hz, 0.01Hz.
3, Load capacity: see table
0.1 Hz Maximum 1.1μF (theoretical value, on-site cable length 1-3 km)
0.05 Hz Maximum 2.2μF (theoretical value, on-site cable length 1-3 km)
0.02 Hz Maximum 5.5μF (theoretical value, on-site cable length 1-3 km)
4, Accuracy: 3% of full scale
5, The voltage positive and negative peak error: ≤ 3% of full scale
6, The voltage waveform distortion: ≤ 5%
7,Usage conditions : indoor, outdoor;
Temperature: -10 ℃ ∽ +40 ℃;
Humidity: ≤ 85% RH
8,Power Supply: AC 50 Hz, 220V ± 5%
Attention should take
1, NAVLF Ultra-low Frequency High Voltage Generator are equipped with a booster, can not use for other ways.
2, If the machine charged, do not try to disassemble and repair, to avoid accidents. If the
3,After shut up the instrument, please use discharging rod to discharge the tested object fully, then dismantle the wire.
4, Before turn on the instrument, please use the discharging rod to discharge the tested object fully.
5, Before turn on and boost, please use the discharging rod to discharge the tested object fully.
Import / export
1.00 Enhet
GODSET PASSERAR FARTYGETS RELING, GODSET PASSERAR FARTYGETS RELING, GODSET PASSERAR FARTYGETS RELING
T/T