NARL-H Automatic Transformer Capacity and Load Load Tester

NARL-H Automatic Transformer Capacity and Load Load Tester

$ 4500 USD / Unit

New

5 Year(s)

China

Inquire

Product description

Product introduction

Electric power system implement two-part tariff: Beside charge by measured charge meter, but also charge the basic tariff according to transformer capacity. For big users, who put into transformer operation, it needs to pay a one-time capacity fee. While with the development of power industry, electricity consumption is increasing, the owned transformer and private contractors have gradually occupied a considerable share, and as follows, in order to pay less, use more, it takes lots of fraudulent means (mainly to change, alter transformer nameplate). Some users steal electricity charge reach to hundreds of thousands, the power sector have suffered no effective means to control yet.

NARL-H Transformer Capacity and Load Load Tester is developed by NANAO ELECTRIC company Electrical specifically for resolving the problem, it’s a high precision instruments developed specifically for transformer capacity and loss parameter measurements. It comes with a high-performance rechargeable battery, can work without external power supply, the charging time can be measured hundreds times continuously; Meanwhile, the internal digital combined as three-phase standard sine wave signal (not simple inverter AC output, which ensure the accuracy of each tested project data under the non-rated conditions ), the power amplifier can provide precise phase AC testing source; and measure transformer capacity and transformers three-phase short-circuit loss tests without external power source, voltage regulator, voltage booster and other auxiliary equipment, simplifying wiring, improved work efficiency greatly; the accuracy of capacity testing results up to 100%. It can be used as two kinds of devices: Active transformer capacity tester + transformer loss parameter tester. It can measure the transformer capacity, load current, load loss, short-circuit loss, impedance voltage and a series of parameters for precision frequency measurements. The NARL-H Transformer Capacity and Load Load Tester has a small size, light weight, high measuring accuracy, good stability, easy to operate etc., which completely replace the conventional method of using multi-table transformer losses and capacity measurement method, simple to connect the wires, test and record, and have greatly improved work efficiency. It has a big screen as a graphic LCD window, graphical menu operation and with a character prompt, set the parameters in a multi-screen display interface, interactive user-friendly, easy to use, is the preferred product for electric users at all levels .

Also called name

Transformer capacity tester,Test instrument transformers

The Characteristics of the products

(1) Can accurately measure the capacity of various distribution transformers, passive measurement , convenient and accurate .

(2) With internal self-powered, which can produce three-phase power of testing power .

(3) Built-in high-performance lithium-ion rechargeable battery, large capacity, full of electricity can be continuous testing more than 500 units.

(4) Can measure the no-load current, no-load loss, short-circuit voltage, short-circuit loss of various types of transformer.

(5) Can correct waveform distortion automatically, temperature correction, voltage

correction (no-load test under the condition of no rated voltage), current correction ( short circuit test under the condition of no rated current) , the operator only need to input calibrated index based on transformer type, it comes to the calculated index results automatically, very suitable for the large capacity transformer unit doing short circuit testing.

(6) Wide range of voltage circuit: the maximum measuring voltage can up to 750V, no need to switch gear to ensure accuracy, will not damage the instrument even you choose the wrong voltage gear.

(7) Capacity measuring range: 20KVA~100000KVA.

(8) With function of indicating the percentage of remaining power of battery, not just simple power loss alarm.


Import / export

1.00 Unit

Free On Board, Cost and Freight, Cost, Insurance and Freight

T/T