SCADA Remote Terminal Unit RTU
Ապրանքի նկարագրությունը
As one of the top SCADA RTU manufacturers, Remote terminal unit scada is a general term for various remote monitoring installed in the distribution network, SCADA remote terminal units has functions such as data collection, control, and communication.
BD-163 distribution automation master terminal unit in SCADA RTU is a new generation of China power distribution box based on the latest generation of automated remote terminal technology from China SCADA RTU manufacturers. The remote terminal unit RTU like our MCC cabinets electrical is the eyes and limbs of the power distribution automation system. The operating status of RTU in SCADA system is related to the data reliability, performance accuracy and operational safety of the power distribution automation. When the configuration is correct and the operation is normal, the SCADA RTU system realizes the correct operation of switches, rapid fault isolation and power restoration, thereby improving power supply reliability.
Types of RTU in SCADA From Manufacturer
BD-163 distribution automation remote terminal (hereinafter referred to as the distribution terminal) is a new generation of power distribution terminal based on the latest generation of automated remote terminal technology.
Centralized Type DTU
Distributed structure, it composed by several interval units and public units.
Distributed Type DTU
Features of Remote Terminal Unit SCADA
Remote terminal unit rtu With "communication", the SCADA RTU system has a "remote maintenance" function.
Flexible configuration, all protection functions have a separate retreat.
The RTU for SCADA system has a complete self-checking function to detect the working conditions of each part online.
The closing and closing circuit adopts an anti-misoperation design and has an anti-missing function.
Applicable to analog acquisition, state quantity acquisition, local and remote control switch closing of 4-12 switch.
24 channels can be controlled by expansion.
By selecting different configurations, remote terminal unit can meet the needs of “Three Remote” and “Two Remote” of the State Grid and South Grid.
Meet the special requirements of all parts of the country (such as Shandong, Beijing, Guangdong, etc.)
Zero-sequence current setting adaptive function, no manual setting required.
Meet the specific requirements of “one or two integration".
The core RTU unit can be flexibly configured to shade vertical, shaded horizontal, outdoor vertical, an d group screen.