AUTO EVA 12 AUTOMATED PARALLEL NITROGEN EVAPORATOR
Описание товара
RayKol Auto EVA 12 is a nitrogen blow-down automated evaporation system that provides automated evaporation of up to 12 samples in parallel with endpoint detection. This automated evaporation system uses vortex airflow generated from stable angled nitrogen blow, to constantly disturb the sample surface and lower its vapor pressure in order to gain gently rapid evaporation under water bath heating. Each sample position is equipped with optical sensor to precisely determine endpoint of concentration. User can have real-time monitoring to whole process through built-in touch screen, make it easier to access and observe.
AUTO EVA 12 AUTOMATED EVAPORATION SYSTEM FEATURES
Batch processing, simultaneous evaporation of up to 12 samples in parallel
Rapid concentration under water bath and nitrogen blowing
Transparent sink design for observation
Good compatibility with various sample vials and ajustable blowing angle
Automatic endpoint detection to avoid over-drying
Sprinkle rinsing to sample vials to maximize recovery rate
AUTO EVA 12 AUTOMATED EVAPORATION SYSTEM SPECIFICATIONS
Parameter Specification
Concentration Water bath heating and nitrogen blowing
Sample capacity 12
Range of concentration temperature Room temperature to 60°C
Sample vials 65mL, 260mL; glass tube with stems
Endpoint detection 1.0mL, 0.5mL
Range of gas flow rate 0 to 5.0mL/min, precise to 0.1mL/min
Software interface 10-inch built-in screen
Dimension 58cm x 46cm x 56cm
Weight 41kg
Power supply 200 to 240V, 50/60Hz
Power rate 1500W
Fume hood/ventilation Required
Storage temperature 0 to 40°C
Storage humidity 20 to 85%
Operating temperature 10 to 40°C
Operating humidity 20 to 80%
AUTO EVA 12 AUTOMATED EVAPORATION SYSTEM APPLICATIONS
Auto EVA 12 Automated evaporation system is designed for large-volume concentration for sample batches, typically used to evaporate extracts of soil and water samples from evironment, azo dye from textiles, fat and acid value from fried foods, as well as residues of pesticides and veternary drugs. It can be applicable in types of analysis such as:
Soil and sediment - Determination of organochlorine pesticides - GC/MS
Solid waste - Determination of polychlorinated biphenyls - GCMS
Textiles ― Determination of the banned azo colourants
AUTO EVA 12 AUTOMATED EVAPORATION SYSTEM BENIFITS
Large sample capacity: each batch can accommodate max. 12 samples, flexible in 65mL and 260mL sample tubes, with endpoint detection.
Gradient nitrogen blowdown: achieve by controlling flow rate of nitrogen gas to increase gradually with time, to ensure efficient evaporation.
Adjustable blowdown angle: optimize the shear vortex action by adjust the angle of the needles pointing, to ensure efficient evaporation.
Sprinkle rinsing: optional configuration of rinising module can boost up the recovery rate of target analytes by flushing back the evaporated analytes.
Automatic water refill: Software control water in and out, with water level sensor to detect endpoint of refill and drain the water bath, to keep it hygiene and clean.
As a reliable automated lab systems manufacturer, we can offer kinds of automated lab equipment for sale, anything you need, please contact us.