1500mAh Li-ion cylindrical battery

Ķīmiskas vielas

PĒC PIEPRASĪJUMA

Jauns

Nav pieejams

Nav pieejams

Jautāt

Apraksts

INR18650-1500mAh Battery,1500mAh Li-ion cylindrical battery,lithium ion battery,cylindrical power lithium-ion batteries

1500mAh Li-ion battery Product Details:

NO. Items    Specifications 

 1 Model   INR18650-1500

 2 Can Material  Ni-Iron 

 3 Rated Capacity  1500 mAh(0.2C5A)

 4  Nominal Voltage   3.7V

 5  Max. Charge Voltage   4.2 V

 6  Discharge Cut-off Voltage   2.75V

 7  Max. Charge Current   1 C5A

 8 Max. Continuous Discharge Current   20 A

 9 Max. Pulse Discharge Current  30A( 2s pulse  )

 10 Max. Diameter(include PVC)  ≤18.30 mm

 11 Max. Height (include PVC)   ≤65.30mm

 12 Weight (Approx.) 43.0g

 13 Impedance (Max. at 1000Hz、charged status)    ≤ 20 mΩ

 14  Charge Method (CC/CV)  Standard   0.5 C5A×3hrs

Quick 1 C5A×2.5hrs.

  15   Operating Temperature  Charge  0℃~45℃ 32oF~113oF

Discharge  -10℃~60℃ -4oF~140oF

Storage  -20℃~45℃ -4oF~113oF

Characteristic of High security rechargeable lithium battery

Without special instructions, the following tests should be done under the condition of : temperature(23℃±3℃), atmospheric pressure (86KPa~106KPa), relative humidity (45%~85%), and the tests should be done within two weeks after receiving the products.

the definitions of some nomenclatures of this specification

standard Charge: Charge with current 0.2C5A to limit charge voltage under the condition of23℃±3℃

surrounding temperature,then change to charge with constant voltage till the current less than or equal to0.02C5A.

Electrical Characteristic for Long life lithium ion battery

NO. Item Standard Test Method

1 Discharge rate capabilities A)1 C5A ≥100% B)10 C5A ≥95% C)15 C5A ≥90% Standard charged under the condition of normal atmospheric pressure and the environmental temperature of 23℃±3℃ and45%~85%RH, then rest for 30mins and discharge at1C5A、5 C5A、10 C5A to the discharge cut-off voltage respectively. Charge/discharge cycle can be conducted for 3times before meeting the Standards(the same below)

2 capacity retention and recovery Residualcapacity≥94% Recoverablecapacity≥*98% Standard charged under the condition of normal atmospheric pressure and the environmental temperature of 23℃±3℃, Stored for 28 days, then discharge at 0.2 C5A to 2.75Vmeasuring residual capacity; Then standard charge/discharge measure recoverable capacity.

3 Low Temperature Performance discharge capacity≥85% rated capacityno distortion and no rupture The cell shall be charged in accordance with the standard charge. Then stored in the temperature of -10℃±1℃ for4h, Discharge at the constant current of 0.2C5A down to the end-of-discharge voltage 2.75V.

4 Cycle Life ≥300cycles Charge: The cell shall be charged in accordance with RapidCharge condition. rest for 10mins.Discharge: 10C5A discharge to 2.75V, one cycle is finished, then rest for 30mins. Then repeat above steps, when capacity is less than 80% of initial capacity, the battery life is over.

Ship

 

The cells might be damaged during shipping by shock. If any abnormal features of the cells are found such as deformation of the cell package, smelling of an electrolyte, an electrolyte leakage and others, the cells shall never be used any more. The Cells with a smell of the electrolyte or a leakage shall be placed away from fire to avoid firing.

 

Storage  

The cell shall be stored at the environmental condition of -20℃ - 45℃ and 65%±20% RH. The voltage for long time storage shall be 3.6V-3.9V range. If the cell has to be storied for a long time (Over 3 months), the environmental condition should be: Temperature: 23℃±3℃ Humidity: 65%±20%RH; please activate the battery once every 3 months according to the following method: Charge with current 0.2C5A until the voltage achieve to 4.0V.