• Venture Road, Jinshan Industrial Zone, Qibin, Hebi
  • Hebi, Henan, 458030
  • China
  • Telefon:86-392-3290973
  • Telefax:86-392-2689866
  • Web:

XKHR-2000 Ash Fusion Analyzer

Messeinrichtungen

$ 1 USD / Sets

New

1 Jahr (e)

China

Erkundigen

Produktbeschreibung

23.XKHR-2000 Ash Fusion Analyzer

Ash Melting Point Detector

Product Name: Ash fusion analyzer

Product Type: XKHR-2000

Scope:

XKHR-2000 Ash fusion analyzer and silicon tubes form a complete set of high temperature furnace,take the camera mode to replace the manual observation is laboratory for determination of ash fusion of intelligent laboratory equipment. Suitable for the determination of coal ash fusion, and the melting process of non-single compound no fixed melting point was measured, the instrument can be widely applied in electric power, coal, metallurgy, tobacco, petrochemical, coal chemical, environmental protection, cement, paper, geological exploration, research institutes and other industries, in line with the national standard GB / T219-2008 "Determination of ash fusion of" requirements.

Features:

1. Suitable for the determination of coal ash melting characteristics, in line with the national standard GB / T219-2008 "Determination of ash fusion of" relevant regulations.

2. Microcomputer programmer using ash melting process control, according to GB AutoComplete ash melting point of the heating process.

3. With a variety of failure prompts, easy to operate, reliable performance.

4. Increase CCD camera, the testing process by the camera to capture images through a display monitor, the image is enlarged 4 times simultaneously, clear and intuitive, high resolution, and no light radiation.

Technical parameters:

Highest temperature: 1500 ℃ ± 3 ℃

Measurement error: ± 3 ℃

Temperature: Before 900 ℃ to 15 ~ 20 ℃ / min

After 900 ℃ to 5 ℃ ± 1 ℃ / min

Timing error: less than 1s/h

Power supply voltage: AC220 (1 ± 10%) V, 50Hz

Maximum current: 30A

Work mode: Continuous

Temperature range: 0 ~ 1600 ℃, resolution 1 ℃, equipped with S value thermocouple.

Time range: 0 ~ 999min, resolution 1min (less than 10min when 1s).

Control: microcontroller as the core, automatic calibration to measure the temperature and current, automatic closed-loop control thyristor phase-shift trigger heating current.

Environment: Temperature 0 ~ 40 ℃, relative humidity less than 80%;


Import / Export

1.00 Sets

FREI AN BORD (... benannter Verschiffungshafen), KOSTEN, VERSICHERUNG UND FRACHT (... benannter Bestimmungshafen)

T/T, L/C