• 东湖高新技术开发区关山大道60号光谷科技产业园8栋
  • 武汉, Hubei, 430074
  • China
  • Tel:+86-153 2720 6266
  • Skype:nanaoelec@yahoo.com
  • Url:

NALF SF6 Gas Detector

NALF SF6 Gas Detector

$ 2000 USD / Unit

New

5 Year(s)

China

Inquire

Product description

Product introduction

NALF SF6 Gas Detector was designed according customers suggestions and actual conditions of power system. It is flexible, steady, fast response, easy to operate, large movable region, can test SF6 breaker, GIS leakage and annual leakage ratio accurately and fast.

Also called name

SF6 detector, SF6 gas detector

The Characteristics of the products

1. Compact size and lightweight: to make the utmost possible effort to use the lightweight materials, easy to transport and carry.

2. Long measurement wire, can test the leakage point of 6M high, with wide moving range.

3. High sensitivity: use perfect designed circuit, reduces the interference by noise and electromagnetic wave, improve the sensitivity.

4. Wide measurement range, multi gears switching: can choose and switch multi gears, and get the standard curve for each gear, quantitative and qualitative tests are available.

5. High accuracy: uses advanced measurement methods, get the high accuracy calibration curve, improve the credibility and accuracy of the test results.

6. Visual display, sound and light alarm: with indicating instrument, if with SF6, the sound and light alarm will work.

7. Fast response, short recovery time: adopts new circuit structure, fast response, short recovery time, greatly convenient to field tests.

8. Built-in self-diagnostic function: the device can supervise self working conditions.

9. Beautiful appearance: packaged with alloy case, all the buttons of the panel with indicators.

10. Long performance life: running time up to 3 hours, applies to field test of SF6 HV switch factories and research institute.

11. Strong anti-interference: fully shielded, eliminate the interference by external and the device.

12. High stability: the power and voltage with high stability, low temperature rise, less thermal losses, good thermal stability, with small null drift and range drift when testing.

13. Good repetitiveness: repeatedly test, good repetitiveness.

14. High reliability: reasonable compact structure, adopts imported components, equipped with over-current, over-voltage protection.

The parameters of the products

1. The minimum detected value: 0.01μL/L

2. Measurement range: 10-30μL/L

100-200μL/L

300-500μL/L

3. Response time:< 1 second

4. Recovery time:< 10 second

5. Indicating error:≤±3%

6. Repetitiveness :≤1%

7. Stability :null drift:< ±1%

range drift:< ±1%

8. Indication means: indicating instrument and sound & light alarm

9. The measurement length of the gun probe:4 meters

10. Running hours: 3 hours

11. Power:220V 50HZ

12. Service condition:temperature:5~45℃

humidity:≤85%

13. Weight:35kg


Import / export

1.00 Unit

Free On Board, Cost and Freight, Cost, Insurance and Freight

T/T